IRtec RAYOMATIC 14 is an infrared thermometer of 8-14 µm spectral response measuring up to 1000°C with a specific design that makes it suitable for a large number of industrial applications, even when the process installation is hardly accessible. The instrument consists in two pieces, a miniature sensing head with separate electronics. The stainless steel sensing head as well as the Teflon-coated cable enables them to resist high ambient temperatures up to 180°C.
The emissivity can be manually adjusted or through a keyboard from 0.10 to 1.00.
Various analogue outputs (0/4-20 mA, 0-10 V, J-type or K-type thermocouple) and optional digital interfaces (USB, RS232) are available. Easily accessible programming keys and a backlit LCD display allow on-site adjustment of essential parameters.
High and low level alarms can be set using the instrument keyboard or from PC. The alarm status is displayed by the display backlit color (blue / green / red). The alarm can be connected to the optional relay output board.
A dual laser pointer integrated in standard shows the actual size of the target (True Target Size, TTS) at different distances. This unique and innovative system overtakes the traditional dual crossed laser pointer and guarantees the identification of the real target surface area regardless of the optics.
Key features of RAYOMATIC 14:
- Monitoring high temperatures to 1000°C
- Accessing to small and high ambient temperature areas with a miniaturized head protected to 180°C
- Making measurements on a very small and defined target with a 95:1 optics or close focus lens Programmable alarms
- Dual red laser pointer with True Target Size system
Infrared temperature measurement
Models | 814-1 | 814-14 | 814-25 | 814-95LS1 |
Temperature range | -40 to 600°C | -40 to 900°C | -40 to 1000°C | -40 to 1000°C |
Spectral response | 8 – 14 µm | |||
Optics D: S | 2:1 | 14:1 | 25:1 | 95:1 |
Accuracy | ± 1% RDG or ± 1°C whichever is greater (T> -20°C; ambient temperature +23°C ± 5°C) | |||
Repeatability | ± 0.5% RDG or ± 0.5°C whichever is greater | |||
Resolution | ± 0.1°C / °F | |||
Temperature coefficient | ± 0.05% / K or ± 0,05 K / K whichever is greater | |||
Response time | 150 ms (95%) | |||
Emissivity | Adjustable from 0.100 to 1.100 manually or digitally | |||
Working temperature | Sensing heads:25:1 miniaturized head: -20 to 180°C
2:1 and 14:1 heads: -20 to 120°C 95:1 TTS head: -20 to 85°C (-20 to 50°C with laser on) Electronic box: 0 to 65 °C |
|||
Calculation functions | Average, max, min, diff, ambient temperature compensation | |||
Digital interfaces | USB, RS232 (option) | |||
Output | Object temperature: 0 – 20 mA / 4 – 20 mA / 0 – 5 V / 0 – 10 V / thermocouple type J ou KHead temperature: 0 – 5 V / 0 – 10 V / 10 mV / K / alarm output
Relays: 2 x 60 VDC/AC, 0.4 A; optically isolated (optional module) |
… [Trackback]
[…] Find More to that Topic: ino.com.vn/aoip/aoip-process-infrared-thermometer-with-deported-head-8-14-µm-modelrayomatic-14/ […]
… [Trackback]
[…] Find More Information here on that Topic: ino.com.vn/aoip/aoip-process-infrared-thermometer-with-deported-head-8-14-µm-modelrayomatic-14/ […]
… [Trackback]
[…] Information to that Topic: ino.com.vn/aoip/aoip-process-infrared-thermometer-with-deported-head-8-14-µm-modelrayomatic-14/ […]