FLuke-Precision Infrared Calibrators (Model:4180/4181)

3
447
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180/81 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations

  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
  • Intuitive, easy-to-read display that indicates when temperature is stable.

The 4180 Series of Precision InfraredCalibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.

The 4180 Infrared Temperature Calibrator reaches temperatures from –15 °C to 120 °C and the 4181 Infrared Temperature Calibrator has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.

In addition, with accuracies as good as ± 0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Emissivity, blackbodies and graybodies
Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." While an ideal surface would have an emissivity equal to 1.00, many of these "blackbody calibrators" have an emissivity of approximately 0.95 (better described as a “graybody”). A true blackbody calibration source would usually be a long cavity with a narrow opening. Unfortunately the opening is usually too narrow to be useful for calibrating common infrared thermometers which require a large target size for an accurate calibration. The advantage of a true blackbody calibration source is that the emissivity is precisely known. Whereas traditional flat plate calibrators have emissivities with uncertainties too large for meaningful calibrations of most thermometers. That is why the 418X Precision Infrared Thermometers are radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.

Specifications
Temperature range (@ 23 °C ambient, 0.95 emissivity)
4180  –15 °C to 120 °C
4181  35 °C to 500 °C
Display accuracy1
4180  ± 0.40 °C at –15 °C
 ± 0.40 °C at 0 °C
 ± 0.50 °C at 50 °C
 ± 0.50 °C at 100 °C
 ± 0.55 °C at 120 °C
4181  ± 0.35 °C at 35 °C
 ± 0.50 °C at 100 °C
 ± 0.70 °C at 200 °C
 ± 1.20 °C at 350 °C
 ± 1.60 °C at 500 °C
Stability
4180  ± 0.10 °C at –15 °C
 ± 0.05 °C at 0 °C
 ± 0.10 °C at 120 °C
4181  ± 0.05 °C at 35 °C
 ± 0.20 °C at 200 °C
 ± 0.40 °C at 500 °C
Uniformity (5.0 in dia of center of target)2
4180  ± 0.15 °C at –15 °C
 ± 0.10 °C at 0 °C
 ± 0.25 °C at 120 °C
4181  ± 0.10 °C at 35 °C
 ± 0.50 °C at 250 °C
 ± 1.00 °C at 500 °C
Uniformity (2.0 in dia of center of target)2
4180  ± 0.10 °C at -15 °C
 ± 0.10 °C at 0 °C
 ± 0.20 °C at 120 °C
4181  ± 0.10 °C at 35 °C
 ± 0.25 °C at 250 °C
 ± 0.50 °C at 500 °C
Heating time
4180  15 min: –15 °C to 120 °C
 14 min: 23 °C to 120 °C
4181  20 min: 35 °C to 500 °C
Cooling time
4180  15 min: 120 °C to 23 °C
 20 min: 23 °C to –15 °C
4181  100 min: 500 °C to 35 °C
 40 min: 500 °C to 100 °C
Stabilization time
 10 minutes
Nominal emissivity3
 0.95
Thermometer emissivity compensation
 0.9 to 1.0
Target diameter
 152.4 mm (6 in)
Computer interface
 RS-232
Power
4180  115 V ac (± 10%), 6.3 A,
 50/60 Hz, 630 W
 230 V ac (± 10%), 3.15 A,
 50/60 Hz, 630 W
4181  115 V ac (± 10%), 10 A,
 50/60 Hz, 1000 W
 230 V ac (± 10%), 5 A,
 50/60 Hz, 1000 W
Fuse(s)
4180  115 V ac 6.3 A, 250 V, slow blow
 230 V ac 3.15 A, 250 V, T
4181  115 V ac 10 A, 250 V, fast blow
 230 V ac 5 A, 250 V, F
Size (HxWxD)
4180  356 mm x 241 mm x 216 mm
 (14 in x 9.5 in x 8.5 in)
4181  356 mm x 241 mm x 216 mm
 (14 in x 9.5 in x 8.5 in)
Weight
4180  9.1 kg (20 lb)
4181  9.5 kg (21 lb)
Safety
 EN 61010-1:2001, CAN/CSA C22.2 No.
 61010.1-04

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | FLuke-Precision Infrared Calibrators (Model:4180/4181).

3 COMMENTS

  1. … [Trackback]

    […] Read More here on that Topic: ino.com.vn/fluke/fluke-precision-infrared-calibrators-model4180-4181/ […]