Overview:
The Sorensen DLM 600 series of programmable power supplies is designed to provide continuously variable
output voltage and current for a broad range of applications in a compact 1U (1.75 inches) high, half-rack
(8.5 inch) wide chassis.
With the use of Zero Voltage Switching (ZVS) technology, these supplies are able to achieve exceptionally low ripple and noise rivaling larger and more expensive linear power supplies. In addition, the high efficiency and fast load transient response assure that the DLM 600 is ideal for even the most demanding applications.
The DLM 600 models are ideal for high density multiple output rackmount requirements or low profile benchtop applications. Output voltages from 0-5VDC to 0-300VDC and currents from 0-2A to 0-75A are available.
The cooling air intake is at the front and sides with exhaust at the rear and sides. Variable speed fans are controlled as a function of ambient air temperature and load, thus reducing acoustic noise and increasing fan life. This allows supplies to be stacked one directly on top of another without space in between, yielding maximum rackmount packing density and a wide operating temperature of 0-50° C. An optional rackmount kit is available to easily mount one or two units side-by-side.
The front panel layout makes the DLM 600 series easy to use. Voltage and current can be set from individual 10-turn potentiometer knobs. Control push buttons include power on, output on, local/remote, voltage/current preview and overvoltage protection preview. Set-point or actual voltage/ current values can be viewed on two 3 ½digit LED displays.
Supplies can be connected in series or parallel. All models automatically accept any standard single phase input without manual set up.
Features And Benefits:
High Power Density
600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required.
Near Linear Ripple & Noise
Near Linear Ripple & Noise: Ripple as low as 2.5mV rms, noise as low as 15mV p-p.
Remote Control
• 16 bit programming through LXI -compliant Ethernet LAN / RS-232C (Option M130)
• 12-bit programming through IEEE-488.2 / RS-232C (Option M9G)
• Standard analog programming 0-5V, 0-10V, or 0-5kΩ.
• isolated analog programming (option)
Pushbutton Preview
Overvoltage protection, voltage and current preview buttons allow viewing these set points at any time with or without the output enabled
Active Down Programming
Standard internal circuitry to speed up response time to down programming changes
Universal AC input
Easy master/slave paralleling with active current sharing
Software:
• IVI-com driver for M130 option
• Labwindows CVI driver for M9G option
• Labview driver for M9G option
Specifications:
Common | |
Remote Sense | The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models |
Remote Programming | Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kΩ |
Remote Monitoring | Voltage or current can be monitored with user selectable ranges, scaled to 0-5 VDC or 0-10 VDC |
Operational Features | Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis. |
Software | IVI-COM, LabVIEW® or LabWindow®/CVI driver for Ethernet and IEEE-488.2 |
Regulatory Compliance | CE Compliant: • Low Voltage Directive (73/23/EEC) using EN 61010-1, and • EMC Directive (89/336/EEC) using EN 61326 Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1 |
Input | |
Voltage and Frequency | 90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz, single phase, 2-wire plus ground |
Current | 11A maximum at 115VAC, 6A maximum at 230 VAC |
Connector | IEC 320 with detachable line cord |
Power Factor | 0.6, typical at full load; dependent on the impedance of the AC input. |
Output | |
Line Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.01% of I max + 2 mA See table for input voltage variation over the AC input voltage range, with constant rated load. |
Load Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.02% of I max + 5 mA See table For 0-100% load variation, with constant nominal line voltage |
Transient Response | 500 μs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change |
Stability | ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature |
Efficiency | 84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75 |
Temperature Coefficient | 0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load. |
Physical | |
Dimensions |
Width: 8.5” (216 mm) |
Weight & Shipping Weight | |
Weight | 9.7 lbs. (4.4 kg) |
Shipping Weight | 12.7 lbs. (5.8 kg) |
Output Ratings | |||
Model | Voltage | Current | Power |
DLM 5-75 | 0-5 VDC | 0-75 ADC | 375 W |
DLM 8-75 | 0-8 VDC | 0-75 ADC | 600 W |
DLM 10-60 | 0-10 VDC | 0-60 ADC | 600 W |
DLM 20-30 | 0-20 VDC | 0-30 ADC | 600 W |
DLM 40-15 | 0-40 VDC | 0-15 ADC | 600 W |
DLM 60-10 | 0-60 VDC | 0-10 ADC | 600 W |
DLM 80-7.5 | 0-80 VDC | 0-7.5 ADC | 600 W |
DLM 150-4 | 0-150 VDC | 0-4 ADC | 600 W |
DLM 300-2 | 0-300 VDC | 0-2 ADC | 600 W |
Output Ratings | ||||
Model | Line Regulation | Load Regulation | ||
Voltage (0.005% of Vmax + 2 mV) | Current (0.01% of Imax + 2 mA) | Voltage (0.005% of Vmax + 2 mV) | Current (0.02% of Imax + 5 mA) | |
DLM 5-75 | 2.25 mV | 9.5 mA | 2.25 mV | 20 mA |
DLM 8-75 | 2.4 mV | 9.5 mA | 2.4 mV | 20 mA |
DLM 10-60 | 2.5 mV | 8 mA | 2.5 mV | 17 mA |
DLM 20-30 | 3 mV | 5 mA | 3 mV | 11 mA |
DLM 40-15 | 4 mV | 3.5 mA | 4 mV | 8 mA |
DLM 60-10 | 5 mV | 3 mA | 5 mV | 7 mA |
DLM 80-7.5 | 6 mV | 2.75 mA | 6 mV | 6.5 mA |
DLM 150-4 | 9.5 mV | 2.4 mA | 9.5 mV | 5.8 mA |
DLM 300-2 | 17 mV | 2.2 mA | 17 mV | 5.4 mA |
Programming Accuracy ¹ | |||
Ethernet (M130/M131) | |||
Model | Voltage (0.1% of VMax) | Current (0.25% of IMax) | OVP (0.5% of 1.1 x VMax) |
DLM 5-75 | 5 mV | 188 mA | 44 mV |
DLM 8-75 | 8 mV | 188 mA | 44 mV |
DLM 10-60 | 10 mV | 150 mA | 55 mV |
DLM 20-30 | 20 mV | 75 mA | 110 mV |
DLM 40-15 | 40 mV | 38 mA | 220 mV |
DLM 60-10 | 60 mV | 25 mA | 330 mV |
DLM 80-7.5 | 80 mV | 19 mA | 440 mV |
DLM 150-4 | 150 mV | 10 mA | 825 mV |
DLM 300-2 | 300 mV | 5 mA | 1.65 V |
Programming Accuracy ¹ | |||
GPIB | |||
Model | Voltage (0.1% of VMax) | Current (0.25% of IMax) | OVP (0.5% of 1.1 x VMax) |
DLM 5-75 | 16 mV | 375 mA | 55 mV |
DLM 8-75 | 16 mV | 375 mA | 88 mV |
DLM 10-60 | 20 mV | 300 mA | 110 mV |
DLM 20-30 | 40 mV | 150 mA | 220 mV |
DLM 40-15 | 80 mV | 75 mA | 440 mV |
DLM 60-10 | 120 mV | 50 mA | 660 mV |
DLM 80-7.5 | 160 mV | 38 mA | 880 mV |
DLM 150-4 | 300 mV | 20 mA | 1.65 V |
DLM 300-2 | 600 mV | 10 mA | 3.3 V |
Display Accuracy | ||
Model | Voltage | Current |
DLM 5-75 | 35 mV | 850 mA |
Resource & DownloadLưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | California Instruments – Sorensen DLM 600 Series.
|
… [Trackback]
[…] Here you can find 66569 more Info on that Topic: ino.com.vn/khac-do-luong-kiem-tra/california-instruments-sorensen-dlm-600-series/ […]
… [Trackback]
[…] There you will find 69219 more Info on that Topic: ino.com.vn/khac-do-luong-kiem-tra/california-instruments-sorensen-dlm-600-series/ […]