DRUCK-Air Data Test System ( Model: ADTS 403)

1
443
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 The ADTS 403 is the latest in a series of reliable, high accuracy, air data test systems designed for avionics laboratory or aircraft ATE rig use.
The compact, rack-mount design has evolved as a result of GE’s continuous research and development, customer feedback and experience gained from manufacturing thousands of automatic pressure controllers. This has enabled performance, ease of maintenance and operational simplicity to be optimized.

Features

  •  High accuracy, RVSM compliant
  •  Legacy ATE systems compatible
  •  Protection for unit under test
  •  Compatible with existing IEEE 488 systems
  •  12 month recalibration period
  •  Programmable test routines and limits
  •  4U high 19" Rack

 Applications

The ADTS 403 is the latest in a series of reliable, high accuracy, air data test systems designed for avionics laboratory or aircraft ATE rig use.

Specifications

The ADTS 403 is a 483 mm (19 in) rack mounted instrument with a local front panel display and keypad. A remote hand held terminal is optional and a matched separate pressure/vacuum supply unit PV 103R is available.

ADTS 403 - Air Data Test System Specifications

Scaling Factors Altitude: ft, meters
Airspeed: knots, km/hr, mph
Rate of Climb: ft/min, m/min, m/sec, hm/min
Others: mbar, inHg, inH2O (4°C, 20°C, 60°F), mmHg, kPa,hPa, psi
Airspeed: CAS (calibrated), TAS (true_ability to enter temperature)
Rate Control/Indication Roc: Rate of Climb
Rt Ps: Rate of Static
Rt Pt: Rate of Pitot
Rt Qc: Rate of Pt-Ps
Rt CAS: Rate of calibrated airspeed
Rt EPR: Rate of engine pressure ratio
Overpressure Negligible calibration change with up to 1.25 x full scale (FS) overload applied.
Calibration Stability Better than 50 ppm per annum.
Recalibration Simple keypad instruction. 12 month interval suggested.Use of a primary pressure standard is recommended, Ruska primary pitot static tester Model 2468.
Display LCD backlit, supertwist/wide angle viewing.
4.8 in x 1.6 in (122 mm x 41 mm) window with four lines of 20 characters 8 mm (0.3 in) high. Optional hand terminal display window 73 mm x 24 mm (2.87 in x 0.95 in).
Response Two readings per second display value update.
Five readings per second interface and control system updates.
Power Supplies 90 to 126 VAC at 47 to 440 Hz, 207 to 260 VAC at 47 to 63 Hz. 200 VA maximum.
Power Failure Protection In the event of a power interruption, the output ports will be vented to ambient conditions safely. On power reconnect, the system is in measure mode.
Self Test Integral test routines and reporting for both electrical and pneumatic systems.
Digital Interfaces Parallel printer interface available as standard.
IEEE-488.2 and earlier versions also available in excess of those detailed. Please refer to GE.
Temperature Range Calibrated: 5°C to 35°C (41°F to 95°F)
Operating: 0°C to 50°C (32°F to 122°F)
Storage: -20° to 81°C (-4° to 178°F)
Sealing Front panel dustproof. Enclosure complies with CE safety requirements.
Humidity 0% to 90% non-condensing
Shock and Vibration Designed to meet section 8, EN61010.
Safety Performance EN61326 for EMC emissions and immunity.
EN61010 for electrical and mechanical safety.
Physical Weight: 13 kg (29 lb) nominal
Case dimensions: 483 mm x 432 mm x 178 mm (19 in x 17 in x 7 in)
Pneumatic Connections Front and rear panel mounted fittings with blanking caps:
Static: AN-6 37° flare
Pitot: AN-4 37° flare
Rear panel mounted fittings with blanking caps Pressure supply: AN-4 37° flare
Vacuum supply: AN-6 37° flare

All fittings are supplied with replaceable filters and 2.5 m (8 ft) long mating hoses. Rear Ps and Pt connections available as an option.

Pneumatic Supplies For normal use, dry, non-corrosive gases with source pressure at a maximum 25% above specified pressure range. PV 103R recommended.

Options

Remote Control Terminal A remote control hand-held terminal complete with approximately 2 m (6 ft) long cable.
Bench Case A case to enclose the instrument for benchtop use.
IEEE-488 Interface (SCPI version) Current air data test systems communications protocol.
IEEE-488 Interface (Honeywell Sperry compatible) Compatible with earlier instruments.
IEEE-488 Interface (Ruska 6610 compatible) Compatible with earlier instruments.
Test Program Manager A software package with serial interface mode adaptor. Permits PC based control and program download for resident test routines. Please refer to product note for further details.
Altimeter Encoder Interface For altimeters with ICAO reporting encoders. Permits display of the bit stream and reporting of altitude value.
ARINC 429 Interface Permits the ADTS to monitor data from an aircraft bus, display the 12 pitot static label information and transmit to the aircraft. Please refer to product note for further details.
Accessories AC power lead—2 m length (6 ft approximately. Ps, Pt, pressure and vacuum hoses—2.5 m lengths (8 ft) approximately. Operators manual and calibration certificate also supplied as standard.
Calibration Standards Instruments manufactured by GE are calibrated against precision calibration equipment traceable to international standards.

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | DRUCK-Air Data Test System ( Model: ADTS 403).

1 COMMENT