Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
HWg-WLD is a network-enabled water leak detector with a water-absorbing sensing cable. HWg-WLD features a built-in web server, SNMP support, and e-mail alert to water flooding. HWg-WLD can remotely control a relay output over the network (a relay is switched when a water leak is detected along the sensing cable).
Basic features
- Ethernet: RJ45 (100BASE-T) (PoE version IEEE 802.3af)
- Web: Built-in web server
- M2M communication protocols: SNMP, XML, Box-2-Box
- Remote output: When a water leak is detected, a remote relay is activated over the network (any Poseidon / Damocles)
- Water flood detector: 2 m (6.5 ft) leader cable +2 m (1.3 ft) sensing cable
- SMS Gateway: Device can send SMS by external "HWg-SMS-GW" without any software.
- Power:
- HWg-WLD: Power adapter
- HWg-WLD PoE: PoE (IEEE 802.3af) + power adapter (depending on type)
- Supported software
- Configuration: UDP Config – IP address configuration and detection (with DHCP)
- HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
- HWg-PDMS: Logging of values, graphs, export to MS Excel, reports
- CapTemp: Visualization on a map, control of outputs, alarm redirection to SMS
- >> Third-party SNMP software
(Nagios, The Dude, Zabbix, IBM Tivoli, HP OpenView, OpManager, IMM (Intellipool Network Monitor), Monitor one, Cacti, MRTG, Opsview, LoriotPro, Axence nvision, Ipswitch WhatsUp, Paessler IPCheck, MSC Operations Manager 2007)
- For programmers: HWg-SDK contains interface descriptions and examples of using M2M protocols in several programming languages
(JAVA, PHP, Borland C++ Builder 6.0, Microsoft Visual C++ 6.0, Borland Delphi 6.0, Microsoft Visual Basic & Excel VBA, VB.NET, C code for Linux, JavaScript (AJAX) Microsoft Visual C# 2005 (.NET)
Water detection | Power | Web | Outputs | ||||||
---|---|---|---|---|---|---|---|---|---|
Spot detection | Detection cable WLD max 85m |
Relay | Remote relay | SNMP Trap | 1-Wire UNI | ||||
HWg-WLD | Power Adaptor | ||||||||
HWg-WLD PoE | Power Adaptor + PoE (IEEE 802.3af) |
||||||||
HWg-WLD Relay | 12V | ||||||||
Flood detector LD-12 | 12V | * | |||||||
*Switching transistor output (no relay output). |
Water sensing cable
- The sensing cable detects even the smallest volume of water, ethylene glycol, or other conductive liquid anywhere on the total length of the cable.
- The sensing cable is terminated with connectors.
- The following can be combined:
- Water sensing cable WLD – 2m
- Water sensing cable WLD – 10m
- Water sensing cable WLD – 50m
- Prolong cable – 5m
- The sensing part of the cable can be up to 85m (280ft) long.
- The cable can be extended anywhere (even between sensing segments) with a 2-wire cable (max 100m – 330ft).
- The WLD water detection cable is reusable (needs to be dried).
Box-2-Box mode
HWg-WLD can directly control relay outputs over the network. No additional software is necessary.
- Supports any Poseidon or Damocles unit
- State is transferred upon changes as well as periodically (default period is 30s). Uses XML over http.
- The output must be in the "Manual" mode (no local condition for activating the output)
- The user configures the remote device IP & port and the remote output ID (ID 151 = Output 1, 154 = Output 4)
- If the relay is write-protected with a password, the user sets the password for controlling the relay
- Output control can be tested with the TEST button
¨
Applications
Typical applications involve monitoring of coolant piping in air conditioning systems or water detection around pipes in technical areas.
- Detection of water leaking from pipes (cable runs along the pipes)
-
Detection cable laid along the walls
-
Under raised floors
-
Above suspended ceilings
-
Detection of water leaks in drip trays
-
Detection of water leaks under A/C outlets
The water leak sensing cable can be wrapped around the piping, suspended under the piping, or laid on the bottom of the pipe duct.
- Can I re-use the sensing cable after flooding?
Yes, the sensing cable can be dried and reused. The time needed to hang-dry the cable depends on the location and air draught. The sensing cable can be dried by hand using a piece of textile or paper cloth in a few minutes. - The supplied sensing cable is only 0.4 m (1.3 ft) long, can I order a longer cable?
Yes, please contact your distributor. The sensing cable can be up to 85 m (280 ft) long. - Is it possible to extend the cable using a regular cable?
Yes, the leader cable can be extended with a two-wire cable by up to 100 m (330 ft). The extension cable must be AWG24 or thicker. - Is it possible to detect the exact flooded spot?
No. HWg-WLD is a product with maximized price/performance ratio. HWg-WLD only detects that a "zone" has been flooded, without precise spot indication. To detect the spot more accurately, more zones must be used. - How can I redirect the water leak alert to SMS?
HWg-WLD can alert you to water leaks by e-mail or SNMP trap.- E-mail can be redirected to SMS using an Email-to-SMS service of your carrier
- SNMP trap can be redirected to SMS using the HWg/PD Trigger application running on a PC with a GSM modem. The application is free of charge and runs on Windows.
- With SNMP, alerts can be redirected using a suitable SNMP monitoring suite (Nagios, Paessler, Intellipool…)
- Is it necessary to keep some software running in order to control relays over IP?
No, remote relay control works in the Box-2-Box mode, no software is needed.
Use any Poseidon or Damocles product as your remote relay output. HWg-WLD periodically (30 s) set defined relay output by XML over http. - When is the water leak alert sent to the remote relay? Only upon activation?
No, this is a safety system. Box-2-Box mode updates the information periodically (every 30s by default). - Can I connect more HWg-WLD devices to one Damocles unit?
Yes, but You should respect one HWg-WLD device per one Digital Output of the remote (Poseidon/Damocles) unit. For Example Damocles 1208 with 8 DO is typical used to indicate status of 8 Water Leak zones. - Where can I find the MIB file for connecting with my SNMP software?
The "HWg-STE.mib" file is available at the "System" page. Simply save it and import it into your SNMP software. - Is it possible to power the HWg-WLD over the Ethernet?
Yes. However, you must order the "HWg-WLD PoE" version. The PoE version can be powered either from an A/C adapter, or over the Ethernet (IEEE 802.3af). - How can I create a graph or protocol with recorded leaks?
Use the supplied HWg-PDMS software. Recorded values can be displayed in a graph or exported to MS Excel. - HWg-WLD PoE does not work after connecting to a PoE switch, it only works when powered from the AC adapter. What is wrong?
Most PoE switches require that PoE supply is explicitly enabled for individual ports. Make sure that PoE is enabled for the particular port. - Where can I find the prices of your devices?
Ask our distributors, or request a quote directly from us using the form at this page.
Ordering numbers
OID | Description |
600 507 | HWg-WLD: Ethernet Water Leak Detector HWg-WLD water leak detector. Complete package with a power adapter, CD, 2 m (6.5 ft) leader cable + 2 m (6.5 ft) sensing cable. |
600 521 | HWg-WLD PoE: Ethernet Water Leak Detector HWg-WLD PoE – Water leak detector powered over PoE (IEEE 802.3af). Complete package with a power adapter, CD, 2 m (6.5 ft) leader cable + 2 m (6.5 ft) sensing cable. Ethernet unit with Web & SNMP interface. |
600 492 | J-clips 10 for WLD cable(photo) 10 pieces of J-Clip for WLD cable to floor or applicable surface to prevent detection cable from shifting after installation. J-clips are durable plastic clips with an easy to install, self-adhesive backing. |
HWg-SMS-GW2 | HWg-SMS Gateway start set GSM SMS gateway for sending text messages from other HW group devices over the LAN. Includes an internal GSM modem, an external antenna with 3m cable, a power adapter and a CD. – photo |
OID Description 600 496 WLD A prolong cable 5m (photo)
Prolong non sensitive cable 5m for WLD type A cable. Can be extended up to 100m in total.600 418 WLD sensing cable A – 2m (photo)
Water Leak Detection sensing cable. Water leakage detected along the entire length of the sensing cable. Sensing cable can be extended by other piece of sensing cable.600 465 WLD sensing cable A – 10m(photo1 photo2)
Water Leak Detection sensing cable. Water leakage detected along the entire length of the sensing cable. Sensing cable can be extended by other piece of sensing cable.600 466 WLD sensing cable A – 50m(photo)
Water Leak Detection sensing cable. Water leakage detected along the entire length of the sensing cable. Sensing cable can be extended by other piece of sensing cable.
Accessories
- Poseidon 3468 (Leak indication using a remote 110/230VAC relay, 2 outputs)
- Damocles 1208 (Leak indication for up to 8 leak detectors, 8 outputs)
- 600 379 – 5V STE power adaptor – EU (power adapter, EU version)
- 600 424 – 5V STE power adaptor – USA (power adapter, USA version)
Resource & Download
- HWg-WLD flyer
- HWg-WLD manual
- Configuration: UDP Config
- Latest firmware: Firmware v.1.0.12
MIB available for download from the product GUI
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | HWg-2D surface water leak detector (Model: HWg-WLD.
… [Trackback]
[…] Read More here: ino.com.vn/khac-do-luong-kiem-tra/hwg-2d-surface-water-leak-detector-model-hwg-wld/ […]
… [Trackback]
[…] Info to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-2d-surface-water-leak-detector-model-hwg-wld/ […]
… [Trackback]
[…] Find More on on that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-2d-surface-water-leak-detector-model-hwg-wld/ […]
… [Trackback]
[…] Here you can find 40812 more Info to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-2d-surface-water-leak-detector-model-hwg-wld/ […]