Damocles MINI is Web-relay with 4 digital inputs and control 2 NO/NC relay outputs over the Web and M2M (SNMP, XML, Modbus/TCP). Dry contact event email or SNMP Trap alert.
Control two remote relays and four digital inputs (dry contacts) with a Web interface. Switch a relay or check the input states over an IP network. The Damocles MINI is a SNMP / WEB relay that is typically used to remotely switch On/Off other devices or to measure energy consumption (using pulse counters at the inputs). A typical application is the sending of an email based on Dry contact inputs, remote restart or remote relay control. Relay outputs can be controlled over M2M protocols SNMP, XML over http or Modbus/TCP.
|
foto 1 foto 2 foto 3 |
Features
- Ethernet: RJ45 (10BASE-T)
- WEB: Built-in web server
- Inputs: 4 digital inputs (dry contact)
- Pulse Counter: 32. bit counter on each Digital Input (for connecting S0 pulses)
- Outputs: 2 digital outputs (relays, 24VDC)
- Box-2-Box mode: Outputs are activated by alerts from other devices (Poseidon / Damocles)
- M2M communication protocols: SNMP, XML, Modbus/TCP
- Reaction to changes at the input: SNMP trap, Email (editable text)
- Mechanical: dimension 35 x 102 x 76 [mm]
- Support for programmers: HWg SDK
- Supported software
- HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
- HWg-PDMS: Logging,conversion of pulses to energy, export to MS Excel, reports
- CapTemp: Visualization on a map, control of outputs, alarm redirection to SMS
- >> Third-party SNMP software
(Nagios, The Dude, Zabbix, IBM Tivoli, HP OpenView, OpManager, IMM (Intellipool Network Monitor), Monitor one, Cacti, MRTG, Opsview, LoriotPro, Axence nvision, Ipswitch WhatsUp, Paessler IPCheck, MSC Operations Manager 2007)
Box-2-Box mode
Changes at a dry contact input of one device (A) are sent over the network (SNMP Trap) and reflected at the relay output of the other device (B). Damocles MINI can react to changes at the inputs of another Poseidon or Damocles unit (without any additional software).
Example:
Too high temperature in the datacenter (measured by Poseidon 3266) turns on a warning red light in the IT department in another building (relay output of Damocles MINI).
AN37: Box-2-Box Connection: Poseidon >> Damocles
Applications
- Control the relay over network – switch relay by three clicks on the mouse
- Remote Web-Relay controlled over IP (snmp / xml / Modbus/TCP)
- Pulse counter: energy consumption measurement over IP.
Reading of the consumption in time from electrometers, flow meters, gas meters, .. - Monitoring of sensors of door opening, motion detectors, dangerous gas, etc.
- Connecting of external inputs to SCADA systems
- Remote control over IP – Opening of entry points (doors, gates, pikes and connecting of passage sensors)
- Monitoring of back-up power supply like UPS and Diesel-engines
- Camera systems (door contacts, PIR sensors)
- Measurement of number of persons/vehicles – counting of indoor state and number of passage of persons/vehicles
Which software to use
- Configuration: UDP Config – IP address configuration
- Event processing: PD Trigger – reacts to events
- Monitoring and logging: HWg-PDMS – Monitoring software with MS Excel reporting
- Simple Visualization: SNMPcap – I/O and sensors
- Visualization: CapTemp – Process monitoring and control
- Command line control: PosDamIO – Command-line control of inputs and outputs (see AN29)
- Other applications: Third-party software for Poseidon & Damocles
- For programmers: HWg-SDK contains interface descriptions and examples of using M2M protocols in several programming languages
(JAVA, PHP, Borland C++ Builder 6.0, Microsoft Visual C++ 6.0, Borland Delphi 6.0, Microsoft Visual Basic & Excel VBA, VB.NET, C code for Linux, JavaScript (AJAX) Microsoft Visual C# 2005 (.NET)
Topology
- WEB (HTML)
The state of digital inputs and outputs is displayed on WWW page. The page is automatically reloaded every 5 seconds. On the main HTML page there are links to Flash Setup, update FirmWare and others.. - XML
All values, the information about alarm state including, are accessible in .XML file (values.xml) and any application can easily log it from XML tags – more informations.. - SNMP
SNMP is protocol for management of telecommunication devices, network infrastructure and related technologies. Damocles is fully controlled over SNMP – more informations.. - Modbus/TCP
Modbus/TCP is industry standard for input of sensor values and sensors into visualization and SCADA systems. All sensors values are accessible over Modbus/TCP – more informations.. - Alarms
- SNMP Traps
In a case of Alarm, the device will send you SNMP Trap with a description of Alarm state to defined IP address – more informations.. - Email
Apart from SNMP Trap, in a case of alarm the device can send you Email with a description of Alarm state – more informations..
- SNMP Traps
>> Damocles – communication protocols.
Technical specifications of Damocles MINI
- Ethernet: RJ 45 (10BASE-T – IEEE802.3)
- 4x Digital inputs: prepared for direct contacts connecting
- 2x Relay outputs: relay contacts NC and NO
- Device configuration:
- UDP Config – IP address configuration, etc.. – remotely functions over the network, but only on the local segment of the network,
- Over HTTP – graphic Flash interface – ensured by access password and defined range of IP addresses.
Ethernet port | |
+ Interface | RJ45 (10BASE-T) – 10 Mbit or 10/100 Mbit network compatible |
+ Supported protocols | IP: ARP, TCP/IP (HTTP, Modbus over TCP), UDP/IP (SNMP) |
+ SNMP compatibility | Ver:1.00 compatible, some parts of the ver 2.0 implemented |
Digital inputs | |
+ 4x Digital Inputs | Dry contact / Wet contact directly |
+ Pulse counter | Yes, 32 bits per DI |
Digital outputs | |
+ 2x Relay contacts | up to 5A/110V AC or 5A/24V DC 1x NC and 1x NO for every output |
LED Status indicators | |
+ POWER | Green – power OK |
+ LINK & Activity | Green – Ethernet connectivity |
DIP SWITCH configuration | |
+ DIP1 | Not used |
+ DIP2 – Security | ON = Security mode – remote configuration disabled OFF = Non-Security mode – remote configuration enabled |
Physical parameters | |
+ Voltage requirements | 12-24 V/ 600 mA DC- coaxial power connector (barrel), GND on the shield |
+ Dimensions / Weight | 35 x 102 x 77 [mm] (H x W x D ) / 500 g |
Sample ordering
- How long it takes to supply ordered samples?
We keep the Damocles MINI units permanently on stock and supply them during 24 to 48 hours.
If you confirm the order, we will send you an E-mail and inform you about approximate delivery date. - What kind of guarantee do you provide?
Standard guarantee is 2 years, it´s possible extend it by contract. - Where I can find the prices of devices?
You can ask our distributors or ask for price (by Email or form). - Where I can find the price of Damocles and accessories for my project?
Send us email (see Contacts), or Demand form. Introduce more informations about your project, how many Damocles unities and which accessories do you need. Don´t fotget write us in which software data will be processed or what do you expect from the program. Write us where are you come from too. We can recommend you the installation company in your neigbourhood. - How you will deliver my order?
We use a couple of delivery companies, for express delivery we use FedEx.
Ordering numbers
OID | Popis typu |
600 289 >Quotation |
Damocles MINI set (photo) Recommended start set for the work with Damocles MINI: – Damocles model MINI [600 250] – EU Power adaptor [600080] (photo) (can be replaced by US or UK type) – manual, CD |
600 250 >Quotation |
Damocles MINI (photo) |
600 339 >Quotation |
Damocles MINI 48V (photo) Damocles MINI powered from -48V DC telco standard. Power supply galvanic isolated from Dry Contact Inputs and relay Outputs. |
Damocles accessories
- DB9 LapLink cable 2m [600 063]
Communication cable RS-232 LapLink for PC connecting.
- Power adapter
- European version – 12V / 0,5A [600 080]
- USA version – 12V / 0,5A [600 081]
- UK version (Great Britain) – 12V / 0,5A [600 082]
- Back-up power adapter (EU plug) [600 251]
- PowerEgg – (photo) [600 237]
Detection of external AC voltage (110 up to 230V), controllable AC output (110 up to 230V) - Inputs and Outputs
- DIN relay – 1x switch contact 10 A [600 084]
- DIN relay – 2x switch contacts 10 A with optical signalization [600 085]
- 3x Door contacts (plastic design) [600 120]
3x sensors for detection of door opening – small, light plastic design, apart from test set, we supply them only like multiple of 3rd pieces
Resource & Download
- Damocles MINI
- Damocles MINI Specifications
- Damocles MINI Starting Guide
- Configuration: UDP Config
- Latest firmware: Firmware v.1.0.11
MIB available for download from the product GUI
… [Trackback]
[…] Informations on that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Information to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Read More Information here to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Find More Info here to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] There you will find 5096 additional Information to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Read More here to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Find More to that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Read More Information here on that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]
… [Trackback]
[…] Find More on that Topic: ino.com.vn/khac-do-luong-kiem-tra/hwg-snmp-web-relay-model-damocles-mini/ […]