IVIUM – multi-channel electrochemical analyser (Model: Ivium-n-Stat)

7
505
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 The Ivium-n-Stat offers a complete package. The hardware includes a build-in high-performance Frequency Response Analyser, low current measurement possibility down to 10nA full-scale, and all the standard Electrochemical techniques. All measurement and dataprocessing software is included (for Windows based pc’s)

Ivium-n-Stat:
  • multi-channel Potentiostat/Galvanostat/ZRA
  • standard integrated impedance analyser in each channel:
    10µHz – 250kHz (1 MHz optional)
  • 8 modules/16 channels per frame (stackable up to 64 channels)
  • Floating/grounded operation
Channel configurations: Single:

  • ±2.5A / ±10V
  • ±5A / ±10V
  • ±2A / ±20V
Dual:         

  • 2 x  ±500mA / ±10V
  • 2 x  ±2.5A / ±10V
Frame:

  • 20A or 40A to fit all channel configurations
  • 8 modules/16 channels per frame
  • Stackable up to 64 channels
Key features:
• Wide application range:
The instrument is designed for a wide range of applications, such as battery/fuel cell-testing, electrode development, biotechnology and other Electrochemical Research applications.
• Complete solution:
The Ivium-n-Stat offers a complete package. The hardware includes a build-in high-performance Frequency Response Analyser, low current measurement possibility down to 10nA full-scale, and all the standard Electrochemical techniques. All measurement and dataprocessing software is included (for Windows based pc’s).
• Safety:
The compliance (maximum current or potential) of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.
• Automation:
Multiple analog and digital input & output ports are available for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.
• Expandibility:
Each channel can be expanded with various modules, such as a power booster, multiplexer, etc.
• Hardware:
– Automatic current range selection: 10nA to 10A/1mV to 10V
– Automatic variable noise filter and potentiostat/galvanostat stability settings
– Simultaneous acquisition of current/potential and peripheral analog signals
– Real time data display up to 500 pnts/s. Acquisition up to 100,000 pnts/s is stored in instrument memory
– Applicable scanrates: 1µV/s to 10,000 V/s
– Minimum interval time/resolution: 10µs
– Result optimalisation by automated tuned filters, gain amplifiers and dc-subtraction
Software:
The Ivium-n-Stat is controlled via Ivium's own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is standard included with each instrument.
Ivium-n-Stat software conttrol:
– Control of separate channels individually
– All channels simultaneously 
– Synchronous start
– Data from different channels plotted individually or in 1 single graph
Hardware specs
channel module
System Performance:
4 Electrodes WE, CE, RE and S
Current compliance ±2.5 A   (optional: ±500mA; ±5 A)
Maximum output Voltage ±10 V below 1 A and ±8 V up to 2.5 A
Potentiostat Bandwidth 250 kHz
Stability settings High Speed, Standard, and High Stability
Programmable response filter 1 MHz , 100 kHz , 10 kHz , 1 kHz , 10 Hz
Signal acquisition dual channel 16 bit ADC, 100.000 samples/sec
Potentiostat:
Applied potential range ±10 V, with 0.33 mV resolution
Applied potential accuracy 0.2%, or 2 mV
Current ranges ±10 nA to ±10 A in 10 steps (optional: ±1pA to ±1nA)
Measured current resolution 0.015% of current range, minimum 1 pA
Galvanostat
Applied current resolution 0.33% of applied current range
Applied current accuracy 0.2%
Potential ranges ±10mV, ±100mV, ±1V, ±10V
Measured potential resolution 0.04% of potential range, minimum 400nV
Impedance Analyser
Frequency range 10µHz to 250kHz   (optional: 10µHz to 1MHz)
Amplitude 0.015mV to 1.0V, or 0.03% to 100% of current range
DC offset 16 bit dc offset subtraction, and 2 dc-decoupling filters
Electrometer
Input impedance >1000 Gohm //<8pF
Input bias current <10 pA
Bandwidth >1 MHz
Peripheral connections*
2 Analog in 0 to ±10 V, 16 bits resolution, bandwidth 40 kHz
1 Analog out 0 tp +4 V, 16 bits resolution
1 Digital input, and 3 Digital outputs 0 to +5 V
I-out, and E-out analog monitor for cell current and potential
AC-out ±0.5 V sinewave 10µHz-250kHz with variable attenuation
Channel-X, and Channel-Y inputs ±4 V: to record impedance from peripheral devices
Environment
Size  w x d x h = 3 x 35 x 13 cm
Weight 0.7 kg
PC requirements Windows XP/Vista/7/8, with free USB port
Specifications: Ivium-n-Stat main frame
Slot positions 8
Common connectors GND and combined emergency off control monitor
Power requirements 20A-frame: 100-240 V, 47-63 Hz, 300 W
40A-frame: 100-240V, 47-63Hz, 600W
Interfacing USB 1.1, 2.0 and 3 compliant
Size w x d x h = 47 x 36 x 14 cm
Weight 6.2 kg (no modules)
11.8 kg (with 8 modules)

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | Tel: (+84) 028 73000184 | IVIUM – multi-channel electrochemical analyser (Model: Ivium-n-Stat).

7 COMMENTS

  1. … [Trackback]

    […] Read More to that Topic: ino.com.vn/khac-do-luong-kiem-tra/ivium-multi-channel-electrochemical-analyser-model-ivium-n-stat/ […]

  2. … [Trackback]

    […] Find More Information here to that Topic: ino.com.vn/khac-do-luong-kiem-tra/ivium-multi-channel-electrochemical-analyser-model-ivium-n-stat/ […]